Our offer products

we know thermography and supply some the most reputable universities and companies in the world with our thermal cameras.

TIM HC系列

  • Featuring the latest technological advancements, the TIM HC | Optical Gas Imaging (OGI) Thermal Infrared Camera is capable of delivering the optimum solution for the detection of Methane and other HydroCarbon gases.
  • This optical gas camera is capable of collecting Radiometric Temperature Data, and produces superb thermal images using its 640 x 512 array.
  • The TIM HC’s Easy-to-Use interface allows for intuitive operation, and has low power consumption, less than 5 watts.
  • Weighing in at <765 Grams without a lens, it is compact and portable, enabling users to quickly pinpoint the failure and give clear vision of leaking gases.
  • Great as a stand alone fixed mount or integrates with our UAV Sensor Control Module for aerial use on drones / UAVs.
  • Includes IR Flash Software.


 


 


Features
  • Unmatched Gas Detection
  • Collect Radiometric Temperature Data
  • Integrates with the Sensor Control Module
  • Detects over 15 gases (see “Detectable Gases” tab below)
  • Low Power (<5 Watts)
  • Compact / Portable
  • Light Weight
Specifications
  • Pixel Pitch: 15µm
  • Pixel Resolution: 640 x 512
  • Spectral Band: 3.2µm – 3.4µm
  • NETD Sensitivity: <.025°C at 30°C
  • Frame Rate:
    • 30Hz
    • 25Hz
  • Dynamic Range:
    • 8 bit
    • 14 bit
  • Operation Range: -40°C to 80°C
  • Temperature Range: -55°C to 80°C
  • Accuracy: +/- 1°C
  • Pixel Operability: >99%
  • 20G Shock / 5.8G Vibration
  • Dimensions: 154mm x 60mm x 90mm – without lens
    (LxWxH +/- .5mm)
  • Weight: <765 Grams – without lens
  • Video: NTSC or PAL analog video
  • Humidity: non-condensing b/t 5%-95%
  • Power: 12V (Cooling Engine)
  • USB 2.0 for Electronics Power & Data
  • Shutterless
  • Aluminum Enclosure
Detectable Gases
  •  Benzene – 3.5g/hr
  • Ethanol – 0.7g/hr
  • Ethylbenzene – 1.5g/hr
  • Heptane – 1.8g/hr
  • Hexane – 1.7g/hr
  • Isoprene – 8.1g/hr
  • Toluene – 3.8g/hr
  • Methanol – 3.8g/hr
  • MEK – 3.5g/hr
  • Pentane – 3.0g/hr
  • Xylene – 1.9g/hr
  • Butane – 0.4g/hr
  • Ethane – 0.6g/hr
  • Methane – 0.75g/hr
  • Propane – 0.4g/hr
  • Ethylene – 4.4g/hr
  • Propylene – 2.9g/hr
  • MIBK – 2.1g/hr
  • Octane – 1.2g/hr
  • 1-Pentene – 5.6g/hr
Software Options
  • IR Flash Software
  • Windows 32-bit SDK
  • Linux SDK (x86, x64 and ARM)