Our offer products

we know thermography and supply some the most reputable universities and companies in the world with our thermal cameras.

TIMP Network temperature measuring infrared camera

By increasing processing capacity, TIMP series cameras itself has more detailed features in alarm setting and ROI settings which were only available in thermal imaging analyzer. TIMP series radiometric thermal cameras are fully controlled by thermal imaging analyzer on PC. SDK for thermal imaging analyzer, developed on Windows with C++ language, is provided for customers who develop own version of thermal imaging analyzer or integrate TIMP thermal cameras into own software.

  • Adopted latest version thermal detectors which has better NETD .
  • Better image quality
  • More stable in operation in lower temperature or in higher temperature
  • Better accuracy in measurement
  • Supports Giga Ethernet
  • Added detail functions in Alarm setting and ROI setting on camera unit
  • Compact design of camera case
  • Control of lens motor for focusing and zooming is done by camera itself and does not need separate lens motor control board


Thermal imaging analyzer on PC receives temperature raw data of all pixels via Ethernet from the camera connected to PC, and analyzes temperature data in various ways as user wants.
User can set ROI (Region of Interest) in different patterns to analyze just in ROI or to exclude specific area in the scene, and thermal imaging analyzer create alarm signal and play wave file or frame of image is glittering as set and two alarm relay-outs are available from the camera in addition to alarms on PC, when alarm conditions are met.


 TIMP320/640 Specifications

TIMP320

TIMP640

Remark

Resolution(Pixels)

384×288

640×480

Spectral response

 8-14µm

Un-cooled LWIR micro-bolometer

Thermal Detector

Pixel Pitch

17µm

Thermal Sensitivity          (NETD)

<50mK @f1.0, 30Hz, 300K

<50mK @f1.0, 30Hz, 300K

Shutter-less compatible

Operating temperature     (ambient temperature)

-10℃ to 60℃

(Installing thermal cameras inside housing with built-in fan and heater to keep inside temperature in a certain range, for example, 15 to 25℃, is recommended for use in out of operating temperature range for accuracy in measurement)

 Accuracy of ± 2℃ or ±2 % of reading: only when camera is in the range of ambient temperature and measurement is done in reasonable distance to the object.

Range of temperature         measurement

TIMP320 & TIMP640:

Normal temperature detection mode: -20 ~ 120℃

High temperature detection mode: 0 ~ 500℃

Medical mode: 20 ~ 50℃

 Thermal camera set at normal temperature detection mode has better accuracy in measurement

Control of focus/zoom

TIMP series cameras include circuit for controlling lens motors for focusing and zooming respectively.

Thermal imaging analyzer for TIMP320 and TIMP640 has icons for focusing “+”/”-” and zooming “+”/”-”.

TIMP series model itself controls lens motor for focusing and zooming, and no extra control board is not necessary for control of lens motors.

System

Video Output

BNC connector(composite), HDMI

Temperature

data output

via Ethernet port(Giga E)

Data refresh rate

30Hz

50Hz

Video frame Rate

BNC connector(composite): NTSC 30Hz, PAL 25Hz

HDMI: Selectable

HDMI: 480p, 576p, 720p, 1080i,

1080p selectable

Ethernet

Giga Ethernet(10/100/1000Mbps)

Lens

4.8mm to 250mm lenses, manual/motorized focus, zoom

Athermalized/Macro lens available

PC Software

TIMP320/640: Thermal imaging analyzer

Camera controller

Thermal report

Thermal imaging analyzer for TIMP320/640(Multi-connection): In 2018.